Special Features:
- Unique robust design
- Complete traceability
Uses:
AA402 anchor is designed for industrial rope access (abseiling) and to support a fall arrest load of 15 kN provided a suitable personal shock absorber is used.
Designed as one person anchor point except rescue situation.
Product Warranty:
10 years from date of purchase subject to correct installation, use and maintenance in accordance with manufacturer’s specifications and recommendations.
Important Note:
Failure to supply and/or install proprietary product in accordance with above standards and codes, specifications and instructions voids complete system certification and/or warranty.
Material Used:
Investment Cast 316 Stainless Steel (Eye)
316 Stainless Steel (Threaded Rod)
Finish:
Electro polished
Abseil Capacity:
15 kN
Fall Arrest Capacity:
15 kN
Dimensions:
- Overall length – 175mm
- Eye Diameter – 45 mm x 26 mm
- Rod length – M16 x 110 mm
- Weight – 505 g
Fixing Details:
- 1 x Chemical HILTI HVU2 or equivalent M16 (hole 18 DIA)
- 1 x Through bolt M16 in structural steel (Hole 17 DIA)
Uses:
AA402 anchor is designed for industrial rope access (abseiling) and to support a fall arrest load of 15 kN provided a suitable personal shock absorber is used.
Designed as one person anchor point except rescue situation.
Things To Know:
AA402 is designed for installation in concrete and structural steel. It has been specifically developed for applications in rope access (abseiling) but it can be also used to support a fall arrest load of 15 kN provided a suitable personal shock absorber is used.
Anchor Rating:
The AA402 eyebolt has been independently tested in accordance with AS/NZS 5532:2025 and verified as a 15 kN rated rope access/ fall arrest anchorage device.
Fixing Options:
Use only approved installation chemicals meeting the required performance criteria.
- Suitable for cracked and non-cracked concrete
- Minimum embedment 110mm for chemical anchors
Examples Include:
- Chemical HILTI HVU2 M16 (HOLE 18 DIA) using SRA setting tool
- Chemical Hilti HVU2 or Hilti RE 500 (HOLE 18 DIA) or equivalent
- Through bolt M16 in steel (HOLE 17 DIA)
Concrete Specifications:
Min. concrete strength: 25 Mpa
Min. slab thickness: 150 mm
Min. distance to edge: 200 mm
Min. distance to another anchor: 200mm
Note:
Edge distances less than the stated minimum may be permitted where verified by anchor manufacturer design (e.g. Hilti). Verification must be based on project-specific parameters including concrete strength, embedment depth, anchor size, and edge condition, with documented capacity calculations.
Loading:
Load the eye bolt in shear, not exceeding 20° with the surface it’s installed into unless installed as a through bolt in steel.
Tools Needed for Installation:
Rotary hammer drill, masonry drill bit 14 or 18 (for Hilti HSL), air pump, cleaning brush, SRA setting tool if using Hilti HVU chemset, chemical dispenser gun if using injectable chemset
Installation Steps – M16 Hilti HVU2 chemset in concrete:
- Use Hilti Reo Scan or similar device to avoid drilling the steel reinforcement in concrete.
- Mark the position for hole to be drilled.
- Drill a DIA 18mm x 110mm hole. Ensure the hole is 90° with the drilled surface.
- Clean the hole 3 times with compressed air and cleaning brush.
- Insert one Hilti HVU M16 chemical pack in the hole.
- Using a rotary hammer with SRA setting tool, install the AA402 eyebolt
- Allow sufficient drying time as per Hilti HVU instructions.
Installation Steps – Hilti HIT or Hilti RE-500 or equivalent chemset in concrete:
- Use Hilti Reo Scan or similar device to avoid drilling the steel reinforcement in concrete.
- Mark the position for hole to be drilled.
- Drill DIA 18mm x 110mm hole. Ensure the hole is 90° with the drilled surface.
- Clean the hole 3 times with compressed air and cleaning brush.
- Inject Hilti HIT or RE 500 or equivalent chemical in the hole as per the manufacturer’s instructions.
- Install AA402 by turning it slowly in anti-clockwise direction while pushing it inside the hole. Wipe off the excess chemical and smooth it around the eyebolt like a silicon bead.
- Allow sufficient drying time as per the chemical manufacturer’s instructions.
Installation Steps – M16 through bolt in structural steel:
- Mark the position for hole to be drilled.
- Drill DIA 17mm through hole. Ensure the hole is 90° with the drilled surface.
- Install AA402 with one backing plate (BP2 or BP3) on the back side.
- Clamp down with a M16 washer and lock nut and tighten fully. Ensure minimum of 5 threads are showing when fully tightened.
Proof Load and Certification:
All glued in anchorages must be proof loaded before their initial use and subsequently on regular basis to satisfy the requirements set out in AS/NZS 1891.4:2025 and ISO 22846 (2020).
- Proof load the eye to 7.5 kN for all applications in rope access and fall arrest
- Through bolts must be visually inspected – do not proof load!
Note:
The roof structure must be assessed by a structural engineer unless it is clear to a suitably qualified person that it is capable of withstanding the forces imposed on it during arresting of a fall and during work positioning.
Disclaimer:
All product specifications and technical descriptions, recommendations and other information provided in this document are given as general guidance and advice, and are to be considered in conjunction with Safety Roof Anchors installation instructions and any other data available and applicable to each particular standard product or system. Use of such data is however the user’s sole responsibility taking into account the intended application and actual conditions existing on the specific worksite. Consequent selection of the right product for any particular use remains the user’s ultimate responsibility.
Safety Roof Anchors is therefore not obligated or liable for any direct or indirect, incidental or consequential damages, losses or expenses in connection with, or by reason of the suitability and use of or otherwise, any product or system for any purpose. Implied warranties of merchantability or fitness for any particular purpose are specifically excluded. Safety Roof Anchors maintains a policy of continuous improvement and development, and therefore reserves the right to modify, amend or otherwise alter product and system designs and specification, models and part numbers, colours and pricing etc., without prior notice. Safety Roof Anchors accepts no liability whatsoever for incorrect information, errors or omissions.
Maintenance:
Inspection and load testing required by competent person at intervals not exceeding 12 months as specified in AS 1891.4:2025, and ISO 22846 (2020).
Standards:
AS/NZS 1891.4:2025, AS/NZS 5532:2025