AA406K Swivel Anchor Kit

AA406K Swivel Anchor Kit

Developed mainly for applications in concrete and steel the AA406K anchor point kit features a 360° swivel eye which offers a uniform loading in all directions preventing side loading of a karabiner attachment.

Product Code: AA406-KIT

  • 360° swivel anchor kit
  • AA407 anchor, 120mm disc, M12 x 145mm rod,
  • M12 locknut, 2x M12 hex nut, flat washer
  • All parts grade 316 stainless steel
Share:
Description
Special Features:
  • 360° swivelling anchor point
  • Used for both fall arrest rope access
  • Kit includes 80mm base plate, M12 x 145mm s/s rod, 1 off M12 nylock nut, 1 off M12 washer, 1 off M12 nylon washer

Product Warranty:

10 years from date of purchase subject to correct installation, use and maintenance in accordance with manufacturer’s specifications and recommendations.

Important Note:

Failure to supply and/or install proprietary product in accordance with above standards, specifications and instructions voids complete system certification and/or warranty.

Material Used:

Investment Cast 316 Stainless Steel (eye and base plate)
Grade 316 stainless steel (rod)

Finish:
Electro polish

Abseil Capacity:
15 kN

Fall Arrest Capacity:
15 kN

Dimensions:

  • Length of plate – 95 mm
  • Eye Diameter – 25 mm
  • Base plate diameter – 80 mm
  • Weight of kit – 600 g

Fixing Details:

  • 1 x Chemical HILTI HVU2 M12 or injectable equivalent such as Hilti RE-500 (HOLE 14 DIA)
  • 1x SRA wedge anchor M12x125mm (HOLE 12 DIA)

Things To Know:

AA406K is designed for installation in concrete and steel. It has been specifically developed for applications in rope access (abseiling) but it can be also used to support a fall arrest load of 15 kN provided a suitable personal shock absorber is used. The swivelling action dramatically improves the loading properties and prevents the cross loading of karabiners.

Anchor Rating:

The AA406K swivel anchor has been independently tested in accordance with AS/NZS 5532:2025 and verified as a 15 kN rated rope access/ fall arrest anchorage device.

Fixing Options:

  • Through bolt M12 (HOLE 14 DIA)
  • Chemical HILTI HVU M12 or equivalent (HOLE 14 DIA)

Concrete Specifications:

Min. concrete strength: 25 – 30 Mpa
Min. slab thickness: 150 mm
Min. distance to edge: 200 mm
Min. distance to another anchor: 200mm

Note:

Edge distances less than the stated minimum may be permitted where verified by anchor manufacturer design (e.g. Hilti). Verification must be based on project-specific parameters including concrete strength, embedment depth, anchor size, and edge condition, with documented capacity calculations.

Loading:
sheer as per the diagram

Tools Needed For Installation:

Rebar detector, Rotary hammer drill, masonry drill bit 14, air pump, cleaning brush, setting tool for rods

Installation steps – M12 chemset in concrete:

  1. Use Hilti rebar detector or similar device to avoid drilling the steel reinforcement in concrete.
  2. Mark the position for hole to be drilled.
  3. Drill an M14 x 110mm hole. Ensure the hole is 90° with the drilled surface.
  4. Clean the hole 3 times with compressed air and cleaning brush.
  5. Insert one Hilti HVU M12 chemical pack in the hole.
  6. Using rotary hammer with appropriate setting tool (hex socket), install a stainless steel M12 rod. Ensure the rods have sharp tip. We recommend using SRA rods (AR-P) or Hilti rods with appropriate setting tool.
  7. Allow sufficient drying time as per Hilti HVU instructions. Once dry, install the AA406K.
  8. Install the stainless steel base plate (BP2 80mm), nylon washer, AA406 anchor, M12 washer and clamp down with M12 nylock nut. Tighten the locknut fully and then slack off until the anchor can swivel freely. Ensure minimum of 3 threads are showing.

NOTE: A gasket of quality polyurethane sealant is recommended between the base plate host structure.

Installation Steps – M12 through bolt:

  1. Use Hilti Reo Scan or similar device to avoid drilling the steel reinforcement in concrete.
  2. Mark the position for hole to be drilled.
  3. Drill one M14 through hole. Ensure the hole is 90° with the drilled surface.
  4. Insert M12 stainless steel rod cut to size. Add one backing plate (BP1 120mm or BP2 80mm) to each side of the rod.
  5. Install one M12 washer and one lock nut to the back side and a large nylon washer, AA406 anchor, M12 washer and one M12 lock nut to the front side. Tighten fully using 2 spanners and then slack off just enough to ensure the anchor can swivel freely. Ensure minimum of 8 threads are showing on each side.

Proof Load and Certification:

All chemical and friction anchorages must be proof loaded before their initial use and subsequently on regular basis to satisfy the requirements set out in AS/NZS 1891.4:2025 and ISO 22846 (2020).

  • Proof load rod to 7.5 kN for fall arrest applications
  • Proof load rod to 7.5 kN for applications in rope access.
  • Always proof load the rods, NOT the brackets!

Through bolts must be visually inspected – do not proof load!

Note:

The structure must be assessed by a structural engineer unless it is clear to a suitably qualified person that it is capable of withstanding the forces imposed on it during arresting of a fall and during work positioning.

Disclaimer:

All product specifications and technical descriptions, recommendations and other information provided in this document are given as general guidance and advice, and are to be considered in conjunction with Safety Roof Anchors installation instructions and any other data available and applicable to each particular standard product or system. Use of such data is however the user’s sole responsibility taking into account the intended application and actual conditions existing on the specific worksite. Consequent selection of the right product for any particular use remains the user’s ultimate responsibility.

Safety Roof Anchors is therefore not obligated or liable for any direct or indirect, incidental or consequential damages, losses or expenses in connection with, or by reason of the suitability and use of or otherwise, any product or system for any purpose. Implied warranties of merchantability or fitness for any particular purpose are specifically excluded. Safety Roof Anchors maintains a policy of continuous improvement and development, and therefore reserves the right to modify, amend or otherwise alter product and system designs and specification, models and part numbers, colours and pricing etc., without prior notice. Safety Roof Anchors accepts no liability whatsoever for incorrect information, errors or omissions.

Maintenance:

Inspection and load testing required by competent person at intervals not exceeding 12 months as specified in AS 1891.4:2025, and ISO 22846 (2020).

Standards:

AS/NZS 1891.4:2025, AS/NZS 5532:2025
ISO 22846 (2020)

Item added to cart View Cart Checkout